Assessing the Potential for Bias in PFAS Concentrations during Groundwater and Surface Water Sampling
A technical report that provides guidelines for practical field sampling equipment and procedures to minimize potential bias associated with PFAS sampling due to the use of specific sampling materials or equipment, laboratory sample storage, or stratification of PFAS in water column (surface water and groundwater).
Authors
Jennifer Field, Ph.D.
Oregon State University
Phone: (541) 737-2265
Jennifer.Field@Oregonstate.edu
Trever Schwichtenberg
Dr. Rula Deeb
Geosyntec Consultants
Phone: 510-285-2676
rdeeb@geosyntec.com
Elisabeth Hawley
Malcolm Pirnie, Inc.
Phone: (510) 735-3027
ehawley@pirnie.com
Claire Sayler
Dorin Bogdan
Charles Schaefer, Ph.D.
CDM Smith
Phone: (732) 590-4633
schaeferce@cdmsmith.com
Bill DiGuiseppi
Amanda Struse
Project
Assessing and Mitigating Bias in PFAS Levels during Ground and Surface Water Sampling
Jennifer Field, Ph.D.
Principal Investigator
Oregon State University